Eaton MCB 3P 125A Type B 248032

PRODUCT CODE: 248032
Not in stock

Eaton Moeller series xPole - PLHT/-V MCB. Miniature circuit breaker (MCB), 125A, 3p, B-Char, AC

  • Triple Pole
  • Up to 125 Amps
  • 90x75x81mm
1 day
€ 196.61

DESCRIPTION

MCB Triple Pole 125 Amps Type B Eaton 248032
Product Name: Eaton Moeller series xPole - PLHT/-V MCB
Catalog Number: 248032
Model Code: PLHT-B125/3
EAN: 4015082480325
Product Length/Depth: 90 mm
Product Height: 75 mm
Product Width: 81 mm
Product Weight: 0.658 kg
Compliances: Contact Manufacturer, RoHS conform
Certifications: Contact Manufacturer
Product Specifications
Rated Operational Current For Specified Heat Dissipation (IN): 125 A
10.11 Short-Circuit Rating: Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.4 Clearances and Creepage Distances: Meets the product standard's requirements.
Rated Short-Circuit Breaking Capacity (EN 60898) at 230 V: 0 kA
10.12 Electromagnetic Compatibility: Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Current Limiting Class: 3
Rated Short-Circuit Breaking Capacity (EN 60898) at 400 V: 0 kA
Amperage Rating: 125 A
10.2.5 Lifting: Does not apply, since the entire switchgear needs to be evaluated.
Frequency Rating – Max: 60 Hz
10.2.3.1 Verification of Thermal Stability of Enclosures: Meets the product standard's requirements.
10.8 Connections for External Conductors: Is the panel builder's responsibility.
Rated Short-Circuit Breaking Capacity (IEC 60947-2) at 400 V: 15 kA
Number Of Poles (Total): 3
Rated Short-Circuit Breaking Capacity (IEC 60947-2) at 230 V: 15 kA
Special Features
Ambient temperature hint: a 1 °C increase results in a 0.35% linear reduction of current carrying capacity
Ambient Operating Temperature – Max: 55 °C
Heat Dissipation Per Pole, Current-Dependent: 0 W
Built-in Depth: 75 mm
Features: Additional equipment possible
Connectable Conductor Cross Section (Solid-Core) – Min: 2.5 mm²
10.9.3 Impulse Withstand Voltage: Is the panel builder's responsibility.
Number of Poles: Three-pole
Ambient Operating Temperature – Min: -25 °C
10.6 Incorporation of Switching Devices and Components: Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against Electric Shock: Does not apply, since the entire switchgear needs to be evaluated.
Used with: Miniature circuit breaker, PLHT
Equipment Heat Dissipation, Current-Dependent: 21.4 W
Tripping Characteristic: B
Frequency Rating – Min: 50 Hz
10.13 Mechanical Function: The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.6 Mechanical Impact: Does not apply, since the entire switchgear needs to be evaluated.
10.9.4 Testing of Enclosures Made of Insulating Material: Is the panel builder's responsibility.
Static Heat Dissipation, Non-Current-Dependent: 0 W
Application: Switchgear for industrial and advanced commercial applications
10.3 Degree of Protection of Assemblies: Does not apply, since the entire switchgear needs to be evaluated.
Voltage Type: AC
Number of Poles (Protected): 3
Heat Dissipation Capacity: 0 W
Release Characteristic: B
Width in Number of Modular Spacings: 4.5
10.2.3.2 Verification of Resistance of Insulating Materials to Normal Heat: Meets the product standard's requirements.
10.2.3.3 Resist. of Insul. Mat. to Abnormal Heat/Fire by Internal Elect. Effects: Meets the product standard's requirements.
10.9.2 Power-Frequency Electric Strength: Is the panel builder's responsibility.
Connectable Conductor Cross Section (Solid-Core) – Max: 50 mm²
Degree of Protection: IP20
Over-voltage Category: III
Pollution Degree: 2
10.7 Internal Electrical Circuits and Connections: Is the panel builder's responsibility.
Connectable Conductor Cross Section (Multi-Wired) – Min: 2.5 mm²
Rated Impulse Withstand Voltage (UIMP): 4 kV
10.10 Temperature Rise: The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated Switching Capacity (IEC/EN 60947-2): 15 kA
Connectable Conductor Cross Section (Multi-Wired) – Max: 50 mm²
Type: Miniature circuit breaker\nPLHT
10.2.2 Corrosion Resistance: Meets the product standard's requirements.
10.2.4 Resistance to Ultra-Violet (UV) Radiation: Meets the product standard's requirements.
10.2.7 Inscriptions: Meets the product standard's requirements.
Rated Operational Voltage (UE) – Max: 400 V
Rated Insulation Voltage (UI): 440 V



RATING

IP20