Sort by:

Eaton MCB 1P 10A B Curve 6KA 194819

PRODUCT CODE: 194819
In stock

Eaton Moeller series xPole Home - HN/HN-HX MCB. HN, xPole Home, 1-pole, tripping characteristic: B, rated current In: 10 A, rated switching capacity IEC/EN 60898-1: 6 kA

  • Single Pole
  • Up to 10 Amps
  • 85x73x17.7mm
1 day
€ 5.08

DESCRIPTION

MCB Single Pole 10 Amps B Curve 6KA Eaton 194819
Product Name: Eaton Moeller series xPole Home - HN/HN-HX MCB
Catalog Number: 194819
Model Code: HN-B10/1
EAN: 9010238063037
Product Length/Depth: 85 mm
Product Height: 73 mm
Product Width: 17.7 mm
Product Weight: 0.12 kg
Compliances: RoHS conform
Product Specifications
Rated Operational Current for Specified Heat Dissipation (IN): 10 A
10.11 Short-Circuit Rating: Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.4 Clearances and Creepage Distances: Meets the product standard's requirements.
Rated Short-Circuit Breaking Capacity (EN 60898) at 230 V: 6 kA
10.12 Electromagnetic Compatibility: Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Current Limiting Class: 3
Rated Short-Circuit Breaking Capacity (EN 60898) at 400 V: 6 kA
Amperage Rating: 10 A
10.2.5 Lifting: Does not apply, since the entire switchgear needs to be evaluated.
Frequency Rating – Max: 60 Hz
10.2.3.1 Verification of Thermal Stability Of Enclosures: Meets the product standard's requirements.
10.8 Connections For External Conductors: Is the panel builder's responsibility.
Rated Short-Circuit Breaking Capacity (IEC 60947-2) at 400 V: 0 kA
Number Of Poles (Total): 1
Rated Short-Circuit Breaking Capacity (IEC 60947-2) at 230 V: 0 kA
Special Features: Ambient temperature hint: a 1 °C increase results in a 0.5% linear reduction of current carrying capacity
Ambient Operating Temperature – Max: 75 °C
Heat Dissipation Per Pole, Current-Dependent: 0 W
Built-in Depth: 44 mm
Rated Switching Capacity (IEC/EN 60898-1): 6 kA
Features: Additional equipment possible
Connectable Conductor Cross Section (Solid-Core) – Min: 1 mm²
10.9.3 Impulse Withstand Voltage: Is the panel builder's responsibility.
Number Of Poles: Single-pole
Ambient Operating Temperature – Min: -25 °C
10.6 Incorporation of Switching Devices and Components: Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection Against Electric Shock: Does not apply, since the entire switchgear needs to be evaluated.
Used With: HN, Miniature circuit breaker
Equipment Heat Dissipation, Current-Dependent: 1.9 W
Tripping Characteristic: B
Frequency Rating – Min: 50 Hz
10.13 Mechanical Function: The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.6 Mechanical Impact: Does not apply, since the entire switchgear needs to be evaluated.
10.9.4 Testing of Enclosures Made of Insulating Material: Is the panel builder's responsibility.
Static Heat Dissipation, Non-Current-Dependent: 0 W
Application: Switchgear for residential and commercial applications, xPole Home- Switchgear for residential applications
10.3 Degree Of Protection Of Assemblies: Does not apply, since the entire switchgear needs to be evaluated.
Voltage Type: AC
Number Of Poles (Protected): 1
Suitable For: Flush-mounted installation
Heat Dissipation Capacity: 0 W
Release Characteristic: B
Width in Number of Modular Spacings: 1
10.2.3.2 Verification Of Resistance Of Insulating Materials To Normal Heat: Meets the product standard's requirements.
10.2.3.3 Resist. of Insul. Mat. to Abnormal Heat/Fire by Internal Elect. Effects: Meets the product standard's requirements.
10.9.2 Power-Frequency Electric Strength: Is the panel builder's responsibility.
Connectable Conductor Cross Section (Solid-Core) – Max: 25 mm²
Degree of Protection: IP20
Over-voltage Category: III
Pollution Degree: 3
10.7 Internal Electrical Circuits and Connections: Is the panel builder's responsibility.
Connectable Conductor Cross Section (Multi-Wired) – Min: 1 mm²
Rated Impulse Withstand Voltage (UIMP): 4 kV
10.10 Temperature Rise: The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Connectable Conductor Cross Section (Multi-Wired) – Max: 25 mm²
Type: HN, Miniature circuit breaker
10.2.2 Corrosion Resistance: Meets the product standard's requirements.
10.2.4 Resistance To Ultra-Violet (UV) Radiation: Meets the product standard's requirements.
10.2.7 Inscriptions: Meets the product standard's requirements.
Rated Operational Voltage (UE) – Max: 230 V
Rated Insulation Voltage (UI): 440 V



RATING

IP20